Principles and Applications of Gas Chromatography


I. Brief Description:

1. Gas chromatography is a major scientific and technological achievement that emerged in the 1950s.

2. This is a new separation and analytical technique that has been widely applied in industry, agriculture, national defense, construction, and scientific research.

II. Principle:

1. Chromatographic analysis is a separation and analytical tool for multi-component mixtures.

2. It primarily utilizes the physical properties of substances to separate mixtures and determine the composition of each component in the mixture. Furthermore, it performs both quantitative and qualitative analyses of the individual components within the mixture.

3. A gas chromatograph uses a gas as the mobile phase (carrier gas). After the sample is introduced into the injector, it is carried by the carrier gas into the chromatographic column. Due to differences in the distribution or adsorption coefficients of the various components in the sample between the mobile phase (gas phase) and the stationary phase (liquid or solid phase) within the chromatographic column, under the continuous flow of the carrier gas, each component undergoes repeated partitioning between the two phases, thereby achieving separation of the components within the column. Subsequently, a detector connected downstream of the column detects each component sequentially based on its physicochemical properties.

III. Characteristics:

1. High separation efficiency. It can effectively separate complex mixtures with highly similar physicochemical properties, enabling both qualitative and quantitative analysis. In some cases, a single analysis can simultaneously resolve and quantify dozens or even hundreds of components.

2. High sensitivity—capable of detecting impurity levels as low as ppm or even ppb.

3. Fast analysis speed—typically, the determination of a single sample can be completed within a few minutes or several tens of minutes.

4. Wide range of applications. In terms of organic compound analysis, this method is the most widely used and can analyze approximately 20% of all organic compounds. Moreover, certain inorganic compounds can also be analyzed after being converted into their organic counterparts.

IV. Composition:

1. Gas path system; 2. Sample injection system; 3. Separation system; 4. Temperature control system; 5. Inspection and recording system.

V. Flowchart:

1. Carrier Gas System: This system includes a gas source, a gas purifier, and a gas flow control system. The carrier gas serves as the mobile phase in gas chromatography. In principle, any gas that is non-corrosive and does not interfere with sample analysis can be used as a carrier gas. Commonly used carrier gases include H2, He, N2, and Ar.

2. Injection System: This system includes the injector and the vaporization chamber. Its function is to introduce the sample and instantly vaporize it.

The function of the vaporization chamber is to instantly heat the liquid sample into a vapor, which is then carried into the chromatographic column by the carrier gas.

3. Separation System: Primarily composed of a chromatographic column, this system is the heart of the gas chromatograph. Its function is to separate the sample as it travels through the column.

4. Detection System: The function of the detector is to convert information about the components that have been separated after the column into electrical signals that are easy to record. It then identifies and measures the composition and content of each component, serving as the “eyes” of the chromatograph.

5. Data Processing System: Currently, workstations equipped with operating software packages are widely used. These systems are computer-controlled and can both automatically process chromatographic data and automatically regulate the parameters of the chromatographic system.

6. General Process:

The carrier gas flows out from a high-pressure cylinder, is reduced in pressure to the desired level by a pressure-reducing valve, and then passes through a purification and drying tube to remove impurities. After passing through a pressure-regulating valve and a rotor flowmeter, the carrier gas flows steadily at a constant rate into the vaporization chamber, where it mixes with the sample that has been vaporized. The resulting sample gas is then carried into the chromatographic column for separation. Following separation, each component sequentially flows into the detector along with the carrier gas, after which the carrier gas is vented. The detector converts changes in the concentration or mass of the substances into corresponding electrical signals, which are amplified and recorded on a recorder, thus producing the chromatogram.

Based on the retention times of each peak obtained from the chromatogram, qualitative analysis can be performed. Based on the peak area or peak height, quantitative analysis can be carried out.

VI. Commonly Used Detectors:

1. TCD (Thermal Conductivity Detector)

2. FID (Flame Ionization Detector)

3. FPD (Flame Photometric Detector)

4. NPD (Nitrogen-Phosphorus Detector)

5. ECD (Electron Capture Detector)

7. Hydrogen Flame Ionization Detector (FID):

Principle: Under the high temperatures of the hydrogen-oxygen flame, many molecules dissociate into fragments, generating free radicals and excited-state molecules. This leads to the formation of a high-energy region in the hydrogen flame, composed of these high-energy particles. When organic molecules enter this high-energy region, they become ionized, thereby producing an ionic current signal in the external circuit.

Features: Small size, high sensitivity, small dead volume, and fast response time. However, it is unresponsive to certain substances such as H2, O2, N2, CO, CO2, NO, NO2, CS2, and H2O. It is a destructive detector.

8. Scope of Application:

It is widely used in industries such as public health and epidemic prevention, food hygiene, environmental monitoring, quality supervision, petrochemicals, fine chemicals, pesticides, pharmaceuticals, power generation, baijiu production, mining, as well as in research institutions and colleges and universities.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Share to:

Related News


Design Concept and Application & Construction Control of UV Coating Formulations for Enclosures

In different applications, UV coatings play varying roles, and there are significant differences in their physicochemical properties and the choice of coating types. Generally, the appropriate UV coating is selected based on the application method and conditions, and professional technical personnel should provide guidance.


Oxygen inhibition in UV curing

After UV adhesive is cured by ultraviolet light irradiation, a sticky surface phenomenon may occur—known as oxygen inhibition. The primary cause of this phenomenon is the free-radical polymerization process. Typically, the UV curing process takes place in air, during which oxygen from the atmosphere gradually diffuses into the coating film. This oxygen competes with the free-radical polymerization reaction, effectively consuming the free radicals. As a result, the curing time of the adhesive is prolonged: while the bottom layer of the coating has already cured, the surface layer remains largely uncured, leading to the sticky appearance on the adhesive’s surface.


The Printing Process (Part 2): Printing Methods

Printing methods can be classified according to the relative positions of image and non-image areas on the printing plate. The common printing techniques can be broadly divided into four major categories: letterpress printing, offset printing, gravure printing, and screen printing. It is essential to select the appropriate printing method based on the requirements of the printed material in order to achieve the desired results.